Examinando por Autor "Montalba, Cristian"
Mostrando 1 - 2 de 2
Resultados por página
Opciones de ordenación
Ítem Comprehensive Assessment of Left Intraventricular Hemodynamics Using a Finite Element Method: An Application to Dilated Cardiomyopathy Patients(MDPI, 2021) Franco, Pamela; Sotelo, Julio; Montalba, Cristian; Ruijsink, Bram; Kerfoot, Eric; Nordsletten, David; Mura, Joaquín; Hurtado, Daniel; Uribe, SergioIn this paper, we applied a method for quantifying several left intraventricular hemodynamic parameters from 4D Flow data and its application in a proof-of-concept study in dilated cardiomyopathy (DCM) patients. In total, 12 healthy volunteers and 13 DCM patients under treatment underwent short-axis cine b-SSFP and 4D Flow MRI. Following 3D segmentation of the left ventricular (LV) cavity and registration of both sequences, several hemodynamic parameters were calculated at peak systole, e-wave, and end-diastole using a finite element approach. Sensitivity, inter- and intra-observer reproducibility of hemodynamic parameters were evaluated by analyzing LV segmentation. A local analysis was performed by dividing the LV cavity into 16 regions. We found significant differences between volunteers and patients in velocity, vorticity, viscous dissipation, energy loss, and kinetic energy at peak systole and e-wave. Furthermore, although five patients showed a recovered ejection fraction after treatment, their hemodynamic parameters remained low. We obtained several hemodynamic parameters with high inter- and intra-observer reproducibility. The sensitivity study revealed that hemodynamic parameters showed a higher accuracy when the segmentation underestimates the LV volumes. Our approach was able to identify abnormal flow patterns in DCM patients compared to volunteers and can be applied to any other cardiovascular diseases.Ítem Validation of 4D Flow based relative pressure maps in aortic flows(Elsevier, 2021) Noltea, David; Urbina, Jesús; Sotelo, Julio; Sok, Leo; Montalba, Cristian; Valverde, Israel; Osses, Axel; Uribe, Sergio; Bertoglio, CristóbalWhile the clinical gold standard for pressure difference measurements is invasive catheterization, 4D Flow MRI is a promising tool for enabling a non-invasive quantification, by linking highly spatially resolved velocity measurements with pressure differences via the incompressible Navier–Stokes equations. In this work we provide a validation and comparison with phantom and clinical patient data of pressure difference maps estimators. We compare the classical Pressure Poisson Estimator (PPE) and the new Stokes Estimator (STE) against catheter pressure measurements under a variety of stenosis severities and flow intensities. Specifically, we use several 4D Flow data sets of realistic aortic phantoms with different anatomic and hemodynamic severities and two patients with aortic coarctation. The phantom data sets are enriched by subsampling to lower resolutions, modification of the segmentation and addition of synthetic noise, in order to study the sensitivity of the pressure difference estimators to these factors. Overall, the STE method yields more accurate results than the PPE method compared to catheterization data. The superiority of the STE becomes more evident at increasing Reynolds numbers with a better capacity of capturing pressure gradients in strongly convective flow regimes. The results indicate an improved robustness of the STE method with respect to variation in lumen segmentation. However, with heuristic removal of the wall-voxels, the PPE can reach a comparable accuracy for lower Reynolds’ numbers.