Selection of Bone fragility-Related Features Obtained with Bi-Directional Axial Transmission, Through a Machine Leaming Strategy

Fecha

2021

Profesor Guía

Formato del documento

Articulo

ORCID Autor

Título de la revista

ISSN de la revista

Título del volumen

Editor

IEEE

ISBN

ISSN

item.page.issne

Departamento o Escuela

Escuela de Ingenieria Informatica

Determinador

Recolector

Especie

Nota general

Resumen

Osteoporosis is a widespread public health problem worldwide, characterized by low bone mass, which compromises strength and increases the risk of fracture. Currently, the gold standard for assessing fracture risk is measurement of areal bone mineral density with dual-energy X-ray absorptiometry (DXA). Several ultrasound techniques, such as Bi-Directional Axial Transmission (BDAT) have been presented as alternatives. For the first studies, classification between fractured and non fractured patients was based on classical ultrasonic parameters, such as velocities or cortical thickness and porosity, obtained from an inverse problem. Recently, novel parameters obtained from structural analysis guided wave spectrum images (GWSI) have been introduced. The aim of this study is to merge both points of view and explore which parameters are the most important to obtain a robust classification using a machine learning approach. This study uses the same set of patients used in previous studies with 195 patients associated with 8 ultrasonic parameters and 3 clinical factors (age BMI and cortisone intake). In addition, each patient corresponds to 10 GWSI, from which 32 parameters of structural analysis are extracted per image, leading to a total of 43 features per image. The dataset was divided into 70% of patients (n = 136) as training and 30% as testing (n = 59). The distribution of patients was adjusted for age and target class. The accuracy was calculated for an increased number of features, which ranking was obtained using Recursive Feature Elimination (RFE). The highest accuracy of 71% is obtained with the optimized parameters and a combination between 22 and 25 features. These result, comparable to femoral DXA (AUC = 0.71, adjusted linear regression), opens perspective towards robust detection of patients at risk of fracture with ultrasound.

Descripción

Lugar de Publicación

Auspiciador

Palabras clave

DEEP LEARNING, TRAINING, ULTRASONIC IMAGING, INVERSE PROBLEMS, DATABASES, ULTRASONIC VARIABLES MEASUREMENT, BIDIRECTIONAL CONTROL

Licencia

URL Licencia