HARP-I: A Harmonic Phase Interpolation Method for the Estimation of Motion From Tagged MR Images

dc.contributor.authorMella, Hernán
dc.contributor.authorMura, Joaquín
dc.contributor.authorWang, Hui
dc.contributor.authorTaylor, Michael D.
dc.contributor.authorChabiniok, Radomir
dc.contributor.authorTintera, Jaroslav
dc.contributor.authorSotelo, Julio
dc.contributor.authorUribe, Sergio
dc.date.accessioned2022-11-30T02:46:34Z
dc.date.available2022-11-30T02:46:34Z
dc.date.issued2021
dc.description.abstractWe proposed a novel method called HARP-I, which enhances the estimation of motion from tagged Magnetic Resonance Imaging (MRI). The harmonic phase of the images is unwrapped and treated as noisy measurements of reference coordinates on a deformed domain, obtaining motion with high accuracy using Radial Basis Functions interpolations. Results were compared against Shortest Path HARP Refinement (SP-HR) and Sine-wave Modeling (SinMod), two harmonic image-based techniques for motion estimation from tagged images. HARP-I showed a favorable similarity with both methods under noise-free conditions, whereas a more robust performance was found in the presence of noise. Cardiac strain was better estimated using HARP-I at almost any motion level, giving strain maps with less artifacts. Additionally, HARP-I showed better temporal consistency as a new method was developed to fix phase jumps between frames. In conclusion, HARP-I showed to be a robust method for the estimation of motion and strain under ideal and non-ideal conditions.en_ES
dc.facultadFacultad de Ingenieríaen_ES
dc.file.nameMella_Har2021.pdf
dc.identifier.citationH. Mella et al., "HARP-I: A Harmonic Phase Interpolation Method for the Estimation of Motion From Tagged MR Images," in IEEE Transactions on Medical Imaging, vol. 40, no. 4, pp. 1240-1252, April 2021, doi: 10.1109/TMI.2021.3051092.en_ES
dc.identifier.doi10.1109/TMI.2021.3051092
dc.identifier.urihttp://repositoriobibliotecas.uv.cl/handle/uvscl/7422
dc.languageen
dc.publisherIEEE
dc.sourceIEEE Transactions on Medical Imaging
dc.subjectCARDIAC MRIen_ES
dc.subjectTAGGED MRIen_ES
dc.subjectSPAMMen_ES
dc.subjectCSPAMMen_ES
dc.subjectHARMONIC PHASE ANALYSISen_ES
dc.subjectSINE-WAVE MODELINGen_ES
dc.subjectCARDIAC STRAINen_ES
dc.subjectMOTION ESTIMATIONen_ES
dc.titleHARP-I: A Harmonic Phase Interpolation Method for the Estimation of Motion From Tagged MR Images
dc.typeArticulo
uv.departamentoEscuela de Ingenieria Biomedica
uv.notageneralNo disponible para descarga

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Mella_Har2021_noaccesible_.pdf
Tamaño:
3.28 MB
Formato:
Adobe Portable Document Format
Descripción: